| Organic Instrument Laboratory | ||||||||||||||||||||||||||||||||||||||||
|
Semivolatile Organics by GCMS Methods
4625/8270 (2 each) Volatile Organics by GCMS Methods 624/8260 (4 each) BTEX/MTBE by GC Methods 602/8021/8015M (2 each) Chlorinated
Pesticides/Chlorinated Herbicides & PCBs by GC Methods
608/617/8081/8082/8151
(2 each) Organophosphorus Pesticides by GC Methods
614/1657/8141 (2 each) TPH, TPH Fractions &
TPH-DRO by GC Methods TX 1005/TX
1006/8015M/OA-1/OA-2
(1 each) Organic Halogens (TOX, EOX, AOX & TX) (1 each) Polynuclear Aromatic
Hydrocarbon (PAHs) & Carbamate Pesticides By HPLC Methods
8310/632
(1each) |
||||||||||||||||||||||||||||||||||||||||
| Organic Sample Preparation Laboratory | |
|
Samples for semivolatile organic analysis require extraction and concentration prior to analysis. The quality of the results for many analyses may be improved by using sample extract cleanup techniques. Liquid samples are extracted using automated separatory funnel shakers to provide a consistent, thorough mixing of solvent and liquid samples during the extraction process. This removes the human factor allowing the first extraction to be as precise as the last. Solid samples are extracted using sonic disrupters. The disrupters have tips for both high and low concentration samples and all are tuned prior to use to standardize the performance of each. Cleanup of both liquid an solid sample extracts is accomplished using EPA approved gel permeation chromatography (GPC) techniques if appropriate for the method of analysis. The laboratory has both single station and automated multiple position usints. Cleanup techniques for additional methods of analysis use florisil, silica gel or other approved chemicals. |
|
| Metals Laboratory | |||||||||||||||||||||||||||||||||
|
Thermo Jarrell Ash(TJA) Model 61E Trace Analyzer Agilent 7500I ICP-MS Cetac M6000A Automated Mercury
Analyzer |
|||||||||||||||||||||||||||||||||
| Wet Chemistry Laboratory | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Acidity Dissolved Oxygen Phenol Alkalinity Fluoride Phosphorus Bromide Hardness Reactivity CBOD Heterotrophic Plate Counts Residues (TSS,TDS,TVS,TS) Chemical Oxygen Demand Hexavalent Chromium Specific conductance Chloride Ignitability Sulfate Chlorine Iodide Sulfide Coliform bacteria MBAS Sulfite Color Nitrogens Total Organic Carbon Corrosivity Oil & Grease Turbidity Cyanides pH Biochemical Oxygen Demand5 &
7 Dionex DX 500 Gradient Ion Chromatography System Tekmar Dohrmann Phoenix 8000 Total Organic Carbon Analyzer
UV/VIS Spectrophotometers YSI 5100 Dissolved Oxygen Systems Ion Analyzers and ion specific electrodes (ISEs) Parr Bomb calorimeter Pensky-Martens Closed-Cup Flashpoint Testers Mettler DL18 Karl Fischer Titrators Flow Injection Analyzer |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Copyright © 1998 - 2009 ERMI Environmental Laboratories. All rights reserved.